• Solutions
    • Outage Prediction
    • Wildfire Risk Mitigation
    • Underground Monitoring
    • Grid Edge Control
    • Harmonics Measurement
    • Fault Detection & Location
    • System & Asset Monitoring
    • Public Power
  • Products
    • Advanced Applications & Analytics ›
    • Overhead Line Sensors ›
    • Underground Line Sensors ›
    • Dynamic VAR Compensator
    • Professional Services ›
    • Grid Analytics System
    • Ample Analytics
    • Grid Analytics System
    • Ample Analytics
    • MM3ai System
    • MM3 Line Sensor
    • ZM1 Line Sensor
    • MM3ai System
    • MM3 Line Sensor
    • ZM1 Line Sensor
    • UM3 Line Monitor
    • UM1 Line Sensor
    • UM3 Line Monitor
    • UM1 Line Sensor
    • VC10 and Ample
    • VC10 and Ample
    • Engineering Services
    • MM3 Fault Indicator
    • Engineering Services
    • MM3 Fault Indicator
  • Resources
    • Use Cases & Case Studies ›
    • White Papers
    • Datasheets
    • Webinars
    • Use Cases
    • Customer Stories
    • Use Cases
    • Customer Stories
  • About Us
    • Events
    • Press and News
    • Careers
    • AWS Partnership
    • Blog Overview
Contact Us

Home › Products › UM1™ Underground Line Sensor

UM1™ Underground Line Sensor

Gain Visibility of Underground Residential Distribution Systems

Increase visibility of underground residential distribution with Sentient Energy’s UM1. Designed specifically for single-phase underground residential distribution (URD) transformer cabinets, the UM1 monitors both primary and secondary cables to extend visibility, fault detection, and load monitoring further along underground distribution circuits.

Download Data Sheet
sentient-energy-um1 new

The UM1 underground line sensor is an important element of Sentient Energy’s Grid Analytics System™, which consists of the  overhead sensors, UM3+ and UM1 underground sensors, and the Ample® Analytics Platform. The solution provides utilities with increased distribution system visibility to improve reliability and enable data-driven operational decision making.

UM1 Underground Line Sensor Features

Powerful Fault Detection and Data Reporting

The UM1’s advanced sensing capabilities include fault detection and highly accurate measurement of fault magnitudes and load current levels. UM1 data is collected by the Ample Analytics Platform via cellular communications for visualization and analysis. The alerts and data from UM1 can also be configured and integrated to stream into systems such as OMS, ADMS.

Built For Residential Distribution

The UM1 Underground Line Sensor is specifically designed for single-phase transformer cabinets for underground residential distribution. The UM1 chassis is compact and directly powered from the secondary side. There is an externally visible LED integrated with the antenna module. The UM1 performs reliability in harsh outdoor cabinet conditions and is certified to IEEE-495.

Flexible Configurations

The UM1’s basic configuration includes monitoring of load and faults on the primary side of the transformer, plus GPS for location. The advanced version of the UM1 adds monitoring of load and faults on the secondary side of the transformer, including sensing current direction. It also includes an externally visible LED integrated with the antenna module. 

UM1 Underground Line Sensor Applications

Underground Fault Detection & Location

Sentient Energy’s UM1 underground line sensor uses advanced fault detection algorithms to detect power system faults including permanent, momentary, and faults without interruption.  The UM1 notifies grid operators of faults via cellular communications.

With highly accurate fault measurement certified for IEEE-495, the UM1 reduces patrol times and helps restore power more quickly, providing significant improvements in reliability metrics.

sentient-energy-UM1 Completed Install GE Prolec ANSI Type2 1
sentient-energy-sentient map

Estimated Distance to Fault

UM1 can significantly cut down the fault finding and repair time by providing an estimated distance of where the fault could be from the nearest UM1. With a very simple setup of cable and circuit impedance parameters, Ample automatically calculates estimated fault location from the device that was closest to the fault. Our proprietary algorithm has been benchmarked to be at par or better than other manual distance to fault calculators in use today.

Transformer Monitoring

The advanced version of the UM1 monitors both voltage and current on secondary side and current on primary side of URD transformers. UM1 sensor data allows utility engineers to detect voltage sags below the 114V ANSI minimum and identify when transformer load exceeds seasonal loading targets.  This data can drive improvements in power quality and asset management.

sentient-energy-um1 trans mon

Increase Visibility of Underground Residential Distribution

Learn how Sentient Energy’s UM1 can help you

Contact Us
Sentient Energy | Enabling the Energy Transition

We help utilities deliver safe, reliable and efficient power.

Copyright © 2009–2025 Sentient Energy, Inc. All rights reserved | Privacy Policy
Contact Us

Solutions

Resources

Twitter Linkedin
  • Solutions
    • Outage Prediction
    • Wildfire Risk Mitigation
    • Underground Monitoring
    • Grid Edge Control
    • Harmonics Measurement
    • Fault Detection Location
    • System & Asset Monitoring
    • Public Power
  • Products
    • Advanced Applications & Analytics
      • Grid Analytics System
      • Ample Analytics
    • Overhead Line Sensors
      • MM3ai System
      • MM3 Line Sensor
      • ZM1 Line Sensor
    • Underground Line Sensors
      • UM3 Line Monitor
      • UM1 Line Sensor
    • Dynamic VAR Compensator
      • VC10 and Ample
    • Engineering Services
      • Engineering Services
      • MM3 Fault Indicator
  • Customer Success
  • Resources
    • Use Cases & Case Studies
    • White Papers
    • Datasheets
    • Webinars
  • About Us
    • Events
    • Press
    • Careers
    • AWS Partnership
    • Blog Overview
Contact Us
Follow Along:
Twitter Linkedin