Home › Optimizing Voltage w Distributed PV Solar

Use Case

Optimizing Voltage with Distributed PV Solar

Download PDF
Residential roof top solar applications cause rapid and extreme voltage fluctuations due to solar intermittency and irradiance changes from cloud covers. These variations can create high-band voltage violations and cause power quality issues and customer dissatisfaction. Existing voltage regulation assets are usually too slow and not sufficiently distributed to address widespread fluctuations. The challenge becomes more critical when states legislate aggressive Renewable Portfolio Standard mandates.

The Grid Edge Control Solution

Sentient Energy’s Grid Edge Control includes the VC10 Dynamic VAR Compensator and Ample software and addresses the challenge of optimizing voltage on distribution systems with high PV solar usage. The solution optimizes voltage at the edge of the grid for greater precision.

sentient-energy-sentient pv solar image 1

How It Works

  1. Reduced Fluctuations – Adding VC10 compresses the voltage profile and reduces voltage fluctuations by injecting reactive power.
  2. Daytime Operations – During daytime, the VC10 units provide dynamic VAR support to compensate for PV generation fluctuation due to clouds. VC10s reduce PV induced ramp rates during evening time when solar generation reduces and load increases.
  3. Nighttime Operations – For nighttime operation, the VC10 units provide full kVAR support during peak-load times when PV generation is not available.
  4. Increased PV Integration – Reduced fluctuations allow utilities to lower load tap changer setpoints to allow for additional PV installations and save energy.

Results

The Sentient Energy Grid Edge Control solution has been proven in field deployments to reduce voltage fluctuations due to PV generation and enable additional PV solar hosting. Utilities using Grid Edge Control also benefit from greater visibility of edge voltage, energy savings, improved power quality and reduced load tap changer operations.

Sentient Energy | Enabling the Energy Transition

We help utilities deliver safe, reliable and efficient power.

Copyright © 2009–2025 Sentient Energy, Inc. All rights reserved | Privacy Policy
Contact Us

Solutions

Resources

Twitter Linkedin
  • Solutions
    • Outage Prediction
    • Wildfire Risk Mitigation
    • Underground Monitoring
    • Grid Edge Control
    • Harmonics Measurement
    • Fault Detection Location
    • System & Asset Monitoring
    • Public Power
  • Products
    • Advanced Applications & Analytics
      • Grid Analytics System
      • Ample Analytics
    • Overhead Line Sensors
      • MM3ai System
      • MM3 Line Sensor
      • ZM1 Line Sensor
    • Underground Line Sensors
      • UM3 Line Monitor
      • UM1 Line Sensor
    • Dynamic VAR Compensator
      • VC10 and Ample
    • Engineering Services
      • Engineering Services
      • MM3 Fault Indicator
  • Customer Success
  • Resources
    • Use Cases & Case Studies
    • White Papers
    • Datasheets
    • Webinars
  • About Us
    • Events
    • Press
    • Careers
    • AWS Partnership
    • Blog Overview
Contact Us
Follow Along:
Twitter Linkedin